Outdoor lighting is specified in layers, not in fixtures, and any one layer on its own fails at exactly the job it was bought for.
The published specification is LED lighting in four layers - task, ambient and dining, accent, and safety - on smart dimmers with motion sensors. Task lighting is published at 3,000-4,000K for food-preparation color accuracy, ambient and dining lighting at 2,700K warm white with commercial-grade string lights rather than residential, accent as under-counter LED strips and uplights, and safety as 12-volt low-voltage path lights with stair riser lights, which are code required for steps with 3+ risers. Fixtures are specified as IP65+ rated and weatherproof. A low-voltage lighting package is published at 500 - 1,500 installed, and the site-wide project band is 15,000 and 35,000. Tampa Outdoor Kitchens is a free matching service, not a provider.
| Job | Published 2026 range |
|---|---|
| Built-in gas grill, installed | 1,500 - 5,000 |
| Pizza oven, installed | 1,000 - 8,000 |
| Outdoor-rated refrigerator | 800 - 3,500 |
| Sink with plumbing | 300 - 2,000 |
| Gas line run from the meter | 400 - 2,000 |
| Low-voltage lighting package | 500 - 1,500 |
| Running gas, water and electric lines together | 2,000 - 5,000 |
| Underground line runs and trenching | 500 - 2,000 |
| Permit allowance | $75 - $400 |
| Removal or demolition, per unit | 25 - 60 |
Lighting over a cooking surface is a task spec, not a mood board. The published layers are ranked by job, and each one carries its own color temperature.
| Layer | Published specification | What it is for |
|---|---|---|
| Task | LED strip lights under the pergola beams over the grill and prep areas, 3,000-4,000K | Food-preparation color accuracy, bright enough to read meat thermometers after sunset |
| Ambient and dining | Dimmable pendants over the dining table, 2,700K warm white; commercial-grade string lights over the seating area | Eating, talking and entertaining without glare |
| Accent | Under-counter LED strips on the bar and kitchen base; uplights on trees and landscape features | Depth, separation and architecture after dark |
| Safety | Path lights along walkways and steps, 12-volt low voltage; stair riser lights | Footing and visibility on the route in and out |
Two published details decide whether the task layer works at all: 3,000-4,000K is specified for food-preparation color accuracy rather than the warmer domestic tone, and the strip has to be bright enough to read a meat thermometer after sunset. A warm decorative strip over a grill is a good-looking failure.
The published lighting guidance states it plainly: any one layer alone fails. Task lighting without ambient produces a glare-lit workbench and ambient lighting without task is atmospheric but unsafe over a hot grill. That is not a style opinion, it is the reason a lighting plan is quoted as a system rather than as a fixture count.
In practice the failure looks like this: a single bright source over the grill casts a shadow into the prep area and blinds everyone facing it; strip light alone leaves the dining table in the dark and the walkway unlit; decorative string lights alone are the arrangement that makes a hot grill unsafe at night.
| What is installed | What is missing | Result |
|---|---|---|
| Task only | Ambient | A glare-lit workbench |
| Ambient only | Task | Atmospheric but unsafe over a hot grill |
| Accent only | Task and safety | Beautiful walls, dark counters, unlit steps |
| All four layers | Nothing | Each layer covers the others' weakness |
String lights are published with their own qualifier: commercial-grade, not residential. Residential strings are not built for permanent outdoor installation, and the published list of what to look for on anything that lives outside is marine-grade or weather-rated construction, sealed electrical connections, and covers rated for UV exposure.
All lighting is published on smart dimmers with phone or voice control, with scenes for Cooking, Dining and Party, and motion sensors for the safety lights. Scenes exist because a kitchen at midnight and a kitchen during a party are not lit the same way, and dimming is what makes a single installation cover both.
Control is only as good as the circuit plan. Published guidance is that the electrical plan puts the lighting, the fridge and any heater on dedicated circuits, with GFCI outlets code required and at least one at counter level. Strand lighting in the beam line, pendants over the table, under-counter strips and 12-volt path lights are four different loads, and they should not share one switch leg with a fridge.
Voltage and rating matter as much as the layout: path lights are specified at 12-volt low voltage, and fixtures are specified as IP65+ rated and weatherproof. A low-voltage lighting package is published at 500 - 1,500 installed, which is a small line item against the published 2,000 to 5,000 for running gas, water and electric lines to the zone, and the published 500 to 2,000 for the underground line runs and trenching that many quotes leave out.
NRCS Soil Data Access point queries across Riverview return poorly drained Myakka fine sand as the most common map unit, with excessively drained Candler fine sand on the higher ridges and somewhat poorly drained Zolfo fine sand between them; Myakka carries a spodic Bh horizon and a water table that sits within 18 in. of the surface for one to four months in most years (https://soilseries.sc.egov.usda.gov/OSD_Docs/M/MYAKKA.html). An island footing there has to be detailed for a rising water table, not just for bearing capacity.
Riverview is unincorporated Hillsborough County and is served by Hillsborough County Water Resources, which runs 11 community public water systems drawing groundwater from the Floridan Aquifer and buys supplemental finished supply from regional wholesaler Tampa Bay Water. Disinfection is by chlorine or chloramine depending on the system, and the county publishes a separate annual consumer confidence report for each one -- its 2025 reports show no health-based standard violations. Source: https://hcfl.gov/residents/property-owners-and-renters/water-and-sewer/water-quality-reports
Utility accounts: Hillsborough County Water Resources Department · (813) 307-1000
A low-voltage lighting package is published at 500 - 1,500 installed. For context, the typical project range is 15,000 and 35,000, running gas, water and electric lines to the zone is published at 2,000 to 5,000, and underground line runs and trenching add 500 to 2,000 that many quotes leave out.
Because the published guidance is that any one layer alone fails: task lighting without ambient produces a glare-lit workbench, and ambient lighting without task is atmospheric but unsafe over a hot grill. The published layers are task (3,000-4,000K under the pergola beams over the grill and prep areas), ambient and dining (2,700K dimmable pendants and commercial-grade string lights), accent (under-counter strips and uplights), and safety (12-volt path lights and stair riser lights).
Stair riser lights are published as code required for steps with 3+ risers, so any step run of three risers or more needs them. Path lights along walkways and steps are separately published at 12-volt low voltage, and fixtures are specified as IP65+ rated and weatherproof.